搜索结果: 1-10 共查到“分析化学 atomic absorption spectrometry”相关记录10条 . 查询时间(0.062 秒)
Role of a Binary Metallic Modifier in the Determination of Cadmium in Graphite Furnace Atomic Absorption Spectrometry
Binary Metallic Modifier Determination of Cadmium Graphite
2010/9/14
In order to discuss the matrix modifier effect of palladium, iron, and a mixture of palladium and iron for the determination of cadmium in graphite-furnace atomic absorption spectrometry (GF-AAS), we ...
Electrochemical Modification of a Graphite Platform for a Solid Sampling Electrothermal Atomic Absorption Spectrometry of Mercury
Electrochemical Modification Graphite Platform Solid Sampling Electrothermal
2010/9/17
An electrodeposited palladium and iridium/gold mixture has been investigated as a chemical modifier for mercury determination in environmental samples by solid sampling electrothermal atomic absorptio...
Flame Atomic Absorption Spectrometry Determination of Trace Amounts of Nickel Ions in Water Samples after Ligandless Ultrasound-assisted Emulsification Microextraction
Flame Atomic Absorption Spectrometry Determination Trace Amounts Nickel Ions
2010/9/17
In the present work, a new ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) method was developed for preconcentration trace amounts of nickel as a prior step to its determinat...
Highly Sensitive Determination of Cadmium and Lead in Leached Solutions from Ceramic Ware by Graphite Furnace Atomic Absorption Spectrometry Coupled with Sequential Injection-based Solid Phase Extraction Method
Cadmium Ceramic Ware Graphite Furnace Atomic Absorption Spectrometry
2010/9/20
A fully automated pretreatment system based on sequential injection solid-phase extraction (SPE) coupled to a graphite furnace atomic absorption spectrometer (Auto-Pret-GFAAS system) was developed to...
Preconcentration and Determination of Trace Amounts of Heavy Metals in Water Samples Using Membrane Disk and Flame Atomic Absorption Spectrometry
preconcentration atomic absorption spectrometry
2007/12/20
摘要 A fast and simple method for preconcentration of Ni2+, Cd2+, Pb2+, Zn2+, Cu2+ and Co2+ from natural water samples was developed. The metal ions were complexed with sodium diethyldithiocarbamate (Na...
Determination of Pb(II) and Cu(II) by Electrothermal Atomic Absorption Spectrometry after Preconcentration by a Schiff Base Adsorbed on Surfactant Coated Alumina
determination of lead and copper preconcentration
2007/12/20
摘要 1,2-Bis(salicylidenamino)ethane loaded onto sodium dodecyl sulfate-coated alumina was used as a new chelating sorbent for the preconcentration of traces of Pb(II) and Cu(II) prior to atomic absorpt...
Determination of Copper by Flame Atomic Absorption Spectrometry after Preconcentration with Activated Carbon Impregnated with a New Schiff Base
preconcentration determination copper
2007/12/20
摘要 A simple and reliable method for theextraction and determination of trace amounts of copper(II) ions using activatedcarbon (AC) impregnated by a new Schiff base 5-[(4-heptyloxyphenyl)azo]-N-(4-prop...
Determination of Cadmium, Copper, Iron, Manganese, Lead and Zinc in Lichens and Botanic Samples by Electrothermal and Flame Atomic Absorption Spectrometry
Lichen ETAAS Ni + Pd + TA Copper Iron
2010/4/20
Within the framework of the International Atomic Energy Agency (IAEA) Analytical Quality Control Service (AQCS) Chemistry Unit a research program was initiated for the identification of trace elements...
Determination of Zinc in Aerosol Samples by Discrete Nebulization Flame Atomic Absorption Spectrometry
iron minerals trace elements lead cobalt nickel chromium zinc manganese determination atomic absorption spectrometry
2010/4/22
Determination of Zinc in Aerosol Samples by Discrete Nebulization Flame Atomic Absorption Spectrometry.
Fundamental Noise Studies in Flame Atomic Magneto-Optic Rotation and Atomic Absorption Spectrometry
Atomic magneto-optic rotation spectrometer (AMORS) air-acetylene flame atomiser Faraday configuration
2010/6/29
A study of inherent noise sources present in a purpose built flame atomic magneto-optic rotation (AMOR) spectrometer system was carried out with a view to identifying their sources. Two different opti...